@@ -0,0 +1,107 @@
|
||||
# IP Conflict - CRITICAL ISSUE
|
||||
|
||||
**Date**: 2026-01-21
|
||||
**Status**: ⚠️ **CRITICAL - TWO CONTAINERS USING SAME IP**
|
||||
|
||||
---
|
||||
|
||||
## IP Conflict: 192.168.11.167
|
||||
|
||||
### Both Containers Are Running and Active
|
||||
|
||||
| VMID | Host | Hostname | IP Address | Interface | MAC Address | Status |
|
||||
|------|------|----------|------------|-----------|-------------|--------|
|
||||
| **10233** | r630-01 | npmplus | 192.168.11.167 | eth1 (net1) | BC:24:11:A8:C1:5D | ✅ Running |
|
||||
| **10234** | r630-02 | npmplus-secondary | 192.168.11.167 | eth0 (net0) | **BC:24:11:8D:EC:B7** | ✅ Running |
|
||||
|
||||
---
|
||||
|
||||
## Critical Discovery
|
||||
|
||||
### UDM Pro MAC Address Match
|
||||
|
||||
**UDM Pro shows**: `bc:24:11:8d:ec:b7` for "NPMplus dot 167"
|
||||
**VMID 10234 MAC**: `BC:24:11:8D:EC:B7` ✅ **MATCHES**
|
||||
|
||||
**This means:**
|
||||
- UDM Pro is seeing **VMID 10234** (npmplus-secondary) on r630-02
|
||||
- NOT VMID 10233 (npmplus) on r630-01
|
||||
- Traffic intended for npmplus may be going to the wrong container!
|
||||
|
||||
---
|
||||
|
||||
## Impact
|
||||
|
||||
### Network Routing Conflicts
|
||||
|
||||
1. **Both containers claim same IP**: 192.168.11.167
|
||||
2. **Both are running**: Both have the IP active
|
||||
3. **MAC address conflict**: UDM Pro sees VMID 10234's MAC
|
||||
4. **Traffic routing**: Traffic may be going to wrong container
|
||||
5. **Connectivity issues**: Explains why NPMplus is inconsistent
|
||||
|
||||
### Why This Causes Problems
|
||||
|
||||
- ARP table conflicts (which MAC responds?)
|
||||
- UDM Pro port forwarding may target wrong container
|
||||
- Network traffic split between two containers
|
||||
- Service availability unpredictable
|
||||
|
||||
---
|
||||
|
||||
## Resolution
|
||||
|
||||
### Option 1: Reassign VMID 10234 (Recommended)
|
||||
|
||||
**VMID 10234** (npmplus-secondary) should be reassigned to a different IP.
|
||||
|
||||
**Recommended IP**: `192.168.11.168` (next available)
|
||||
|
||||
**Steps:**
|
||||
1. Stop VMID 10234
|
||||
2. Change IP from 192.168.11.167 to 192.168.11.168
|
||||
3. Restart container
|
||||
4. Verify no conflicts
|
||||
|
||||
### Option 2: Remove VMID 10234 IP
|
||||
|
||||
If npmplus-secondary is not needed:
|
||||
1. Stop VMID 10234
|
||||
2. Remove IP assignment
|
||||
3. Keep container for other purposes
|
||||
|
||||
---
|
||||
|
||||
## Verification After Fix
|
||||
|
||||
After reassigning VMID 10234:
|
||||
|
||||
```bash
|
||||
# Verify no conflicts
|
||||
# Check r630-01
|
||||
pct config 10233 | grep 192.168.11.167
|
||||
|
||||
# Check r630-02
|
||||
pct config 10234 | grep 192.168.11.168
|
||||
|
||||
# Verify UDM Pro sees correct MAC
|
||||
# Should see BC:24:11:A8:C1:5D for 192.168.11.167
|
||||
```
|
||||
|
||||
---
|
||||
|
||||
## Summary
|
||||
|
||||
**Status**: ⚠️ **CRITICAL IP CONFLICT**
|
||||
|
||||
**Conflict**: Two containers using 192.168.11.167
|
||||
- VMID 10233 (npmplus) on r630-01
|
||||
- VMID 10234 (npmplus-secondary) on r630-02
|
||||
|
||||
**UDM Pro is seeing**: VMID 10234 (wrong container!)
|
||||
|
||||
**Action Required**: Reassign VMID 10234 to different IP (192.168.11.168)
|
||||
|
||||
---
|
||||
|
||||
**Next Step**: Fix IP conflict by reassigning VMID 10234
|
||||